DOWNLOADS

Overview

Taskgroup 18 Images - Version 4
Taskgroup 18 Images - Version 3
Readout of Human Observer
article: N. Karssemeijer, M.A.O. Thijssen, "Determination of contrast-detail curves of mammography systems by automated image analysis"
European guidelines for quality assurance in breast cancer screening and diagnosis (PDF)
CDCOM version 1.6 and CDCOM readme (CDMAM3.4)
Chapter 11 of the European Guidelines for Quality Assurance in Breast Cancer Screening and Diagnosis
Physico-Technical Protocol
Euref type test protocol version 1.2
CDCOM evaluation [Compatibiliteitsmodus]
Examples Homogeneity test.pdf
CDMAM Analyser version 1.5.5
Programme EUREF training Course - Vienna 11 March
Definitive Programme EUREF Training Course - Vienna 11 March 2013
EUREF tomo protocol version 0.10
Supplement phys-techn protocol 4th edition Guidelines version 1.0 website EUREF
Supplement 4th edition European Guidelines
EUREF Tomosynthesis Protocol version 0.15
Presentation Tomosynthesis Vienna ECR2014
Programme Workshop on QC in Breast Tomosynthesis | Vienna | September 11th 2015
CDCOM version 4.1.0 and CDCOM readme (CDMAM4.0)
European Tomo QC Protocol version 1.01
Update Digital Mammography Protocol 01-2017
EUREF Tomosynthesis Protocol version 1.03
Euref type test protocol version 1.3
 
 
Powered by Phoca Download

Latest news

Updated version of European breast tomosynthesis QC protocol (version 1.03)

Changes compared to version 1.01:

  • The dose reference values have been changed to limiting values.
  • The limiting dose value for 20 mm PMMA thickness has changed from 1.0 mGy to 1.2 mGy. This has been done because feedback was received and was noted that the value of 1.0 mGy was difficult to achieve with sufficient image quality for DBT systems.
  • Some text has been added regarding the mode in which mages have to be made in some methods of measurement.

 

Download the updated version here (bottom of the page).

Updated version of European breast tomosynthesis QC protocol (version 1.01)

Due to the rapid developments the European breast tomosynthesis protocol (version 1.01) has been updated and released.

 

Changes compared to version 1.0:

  • Table 1 has been updated.
  • For scanning geometry DBT systems inherently without projection images it has been mentioned in the description of several measurements that the simple backprojection mode should be used.
  • In the terms of definition the reference ROI in simple backprojection images has been added.
  • In the dosimetry section the s-factor for Rh/Ag has been added.
  • Some small errors has been corrected.

 

Download the updated version here (bottom of the page).

© 2017 EUREF  |  Terms and Conditions EUREF  |  webdesign by Joomla webdesign